Ombili Schulprojekt

SIDE ELEVATION - ABLUTION BLOCK 1 : 150 FRONT ELEVATION - ABLUTION BLOCK 1 : 150 BACK ELEVATION - ABLUTION BLOCK 1 : 150 880 880 115 2900 115 2205 115 230 7210 230 7670 880 115 880 115 880 115 880 115 910 115 2205 7670 1170 1780 115 1010 115 1780 1170 230 7140 230 7600 230 1700 115 1698 115 1698 115 1700 230 7600 NE2 NE2 NE2 NE2 NE2 NE2 PLAN ABLUTION BLOCK - (1 off) 1 : 150 BOYS 18,3 m² GIRLS 18,3 m² 3,7 m² WC WC 3,7 m² 700 6740 700 650 400 2700 250 240 415 2816 1365 1200 100 mm 15 MPa CONCRETE FLOOR ON HARDCORE FILLING COMPACTED IN LAYERS OF 150 mm IBR CEILING ON 75x50x20x2,5mm COLD FORMED LIPPED CHANNEL GALVANISED IBR ROOF SHEETING 50x50x6 mm ANGLE IRON TRUSSES AT MAX. 3650 mm CENTRES AND FIXED TO WALLS BY MEANS OF MS10 U-BOLT 75x50x20x2,5 mm COLD FORMED LIPPED CHANNEL PURLINS AT MAX 1350 mm CENTRES GALVANISED RIDGE CAP WITH IBR RIDGE CLOSURES 15 MPa CONCRETE FOUNDATION NGL DPC CONCRETE LINTELS ABOVE WINDOWS 900 1200 APRON STOEP TYPICAL CROSS SECTION 1 : 75 REVISION CADFILENo DWGNo DRAWN DATE SCALE TITLE AllyCadFiles\OMBILI\CLASSROOMSNEW JUNE2015 PROJECT APPROVED DATE 12 June 2015 AS SHOWN H.Roodt P.O.Box 826 TSUMEB Tel 067-220492 Cell0812780977 HR15/11/4 * LAYOUT PLAN AND DETAILS OMBILI NAMIBIA PROPOSED NEW ABLUTION FACILITIES