Ombili Schulprojekt

Heide Braun House Lowen House DNEG 1992 DNEG 1992 P.P. Land House Flats Old Farm House Storage Room Centre Kindergarden Kindergarden Play Ground Toilets Ombili Primary School 1992 Ombili Primary School 1997 OVTC Silo Carport Ca HR15/11/1 * SITE PLAN OMBILI NAMIBIA PROP. NEW LIBRARY, CLASS ROOMS AND ABLUTION FACILITIES BOYS GIRLS REVISION CADFILENo DWGNo DRAWN DATE SCALE TITLE AllyCadFiles\OMBILI\SITEPLANSCHOOL JUNE2015 PROJECT APPROVED DATE 12 June 2015 AS SHOWN H.Roodt P.O.Box 826 TSUMEB Tel 067-220492 Cell0812780977 LEGEND tic Tank Septic Tank Tree 32 33 34 35 36 37 38 65 66 7 m² 391 m² 407 m² 489 m² CONVERT PART OF OVTC INTO 3 SINGLE FLATS EXISTING BUILDINGS NEW CLASS ROOMS & LIBRARY NEW ABLUTION BLOCK FUTURE CLASS ROOMS

SIDE ELEVATION - ABLUTION BLOCK 1 : 150 FRONT ELEVATION - ABLUTION BLOCK 1 : 150 BACK ELEVATION - ABLUTION BLOCK 1 : 150 880 880 115 2900 115 2205 115 230 7210 230 7670 880 115 880 115 880 115 880 115 910 115 2205 7670 1170 1780 115 1010 115 1780 1170 230 7140 230 7600 230 1700 115 1698 115 1698 115 1700 230 7600 NE2 NE2 NE2 NE2 NE2 NE2 PLAN ABLUTION BLOCK - (1 off) 1 : 150 BOYS 18,3 m² GIRLS 18,3 m² 3,7 m² WC WC 3,7 m² 700 6740 700 650 400 2700 250 240 415 2816 1365 1200 100 mm 15 MPa CONCRETE FLOOR ON HARDCORE FILLING COMPACTED IN LAYERS OF 150 mm IBR CEILING ON 75x50x20x2,5mm COLD FORMED LIPPED CHANNEL GALVANISED IBR ROOF SHEETING 50x50x6 mm ANGLE IRON TRUSSES AT MAX. 3650 mm CENTRES AND FIXED TO WALLS BY MEANS OF MS10 U-BOLT 75x50x20x2,5 mm COLD FORMED LIPPED CHANNEL PURLINS AT MAX 1350 mm CENTRES GALVANISED RIDGE CAP WITH IBR RIDGE CLOSURES 15 MPa CONCRETE FOUNDATION NGL DPC CONCRETE LINTELS ABOVE WINDOWS 900 1200 APRON STOEP TYPICAL CROSS SECTION 1 : 75 REVISION CADFILENo DWGNo DRAWN DATE SCALE TITLE AllyCadFiles\OMBILI\CLASSROOMSNEW JUNE2015 PROJECT APPROVED DATE 12 June 2015 AS SHOWN H.Roodt P.O.Box 826 TSUMEB Tel 067-220492 Cell0812780977 HR15/11/4 * LAYOUT PLAN AND DETAILS OMBILI NAMIBIA PROPOSED NEW ABLUTION FACILITIES

CONCRETE LINTELS ABOVE WINDOWS SUSPENDED CEILING FISSURED VINYL GYPSUM BOARD 1200 x 600 x 12.5 mm 100 mm 15 MPa CONCRETE FLOOR ON HARDCORE FILLING COMPACTED IN LAYERS OF 150 mm OMBILI NAMIBIA PROP. NEW LIBRARY & CLASS ROOMS 1 : 150 REVISION CADFILENo DWGNo HR15/11/3 DRAWN DATE SCALE TITLE * NEW BUILDING EXISTING BUILDING AllyCadFiles\OMBILI\CLASSROOMSNEW JUNE2015 PROJECT APPROVED DATE ELEVATIONS & SECTION 12 June 2015 AS SHOWN H.Roodt P.O.Box 826 TSUMEB Tel 067-220492 Cell0812780977 WEST ELEVATION 1 : 150 NEW BUILDING EXISTING BUILDING EAST ELEVATION 1 : 150 NORTH ELEVATION min 700 6420 700 230 7350 230 300 250 200 2700 900 15 MPa - CONCRETE FOUNDATION GALVANISED RIDGE CAP ROOF : GALVANISED IBR SHEETING ON 75 x 50 x 20 x 2,5 mm COLD ROLLED LPPED CHANNEL PURLINS AT MAX 1350 mm CENTRES STEEL TRUSSES - 50 x 50 x 6 mm ANGLE IRON AT MAX 3000 mm CENTRES DPC NGL SECTION A - A 1 : 75 1515

55,1 m² 55,1 m² 8,5 m² 8,5 m² 67,3 m² PLAN C22H NEX7 1 : 150 A REVISION CADFILENo DWGNo DRAWN DATE SCALE TITLE AllyCadFiles\OMBILI\CLASSROOMSNEW JUNE2015 PROJECT APPROVED DATE 12 June 2015 AS SHOWN H.Roodt P.O.Box826 TSUMEB Tel067-220492 Cell0812780977 A NEX7 D4H C22H NEX7 D4H OMBILI NAMIBIA PROP. NEW LIBRARY & CLASS ROOMS HR15/11/2 * LAYOUT PLAN CLASS ROOM STORE RM 1 STORE RM 2 CLASS ROOM PASSAGE VERANDAH EXISTING STAFF ROOMS EXISTING SEPTIC TANK Tree FUTURE EXTENSIONS EXISTING BUILDING LIBRARY 10000 2000 19420 9770 230 2000 230 8000 230 8000 230 2500 230 1750 230 3388 115 3388 230 230 6890 230 7350 31420

RkJQdWJsaXNoZXIy MjY3NTk=